Many common software questions are answered in the categories below. If you can’t find a response for yours, try checking our User Forum, or, contact HelpDesk for direct assistance
Metrix » Weather |
Q: How are Htg DT and Clg DT calculated?
A: If you are using Max Delta T tuning, the equations are as follows:
Htg DT = Max[(Hi+Lo)/2 - Balance Point]
Clg DT = Max[Balance Point-(Hi+Lo)/2]
If Max Delta T tuning is not selected, the equations are instead:
Htg DT = Average[(Hi+Lo)/2 - Balance Point]
Clg DT = Average[Balance Point-(Hi+Lo)/2]
These equations use the billing period, which is the day after the previous bill end date up to and including the current bill end date.
A: If you are using Max Delta T tuning, the equations are as follows:
Htg DT = Max[(Hi+Lo)/2 - Balance Point]
Clg DT = Max[Balance Point-(Hi+Lo)/2]
If Max Delta T tuning is not selected, the equations are instead:
Htg DT = Average[(Hi+Lo)/2 - Balance Point]
Clg DT = Average[Balance Point-(Hi+Lo)/2]
These equations use the billing period, which is the day after the previous bill end date up to and including the current bill end date.
I can’t find the answer to your question ? Try checking our User Forums.
Otherwise feel free to contact our Tech Support staff at (805) 329-6565, or via email at helpdesk@abraxasenergy.com.